长河落日电视剧全集播放免费观看,精品国产九九,av一区三区,久久99精品久久久久久国产越卉,久久激情综合,操久在线,久久久久久久国产精品

Hi!Welcome to Taian Demei Electromechanical Equipment Co.,Ltd.!
Taian Demei Electromechanical Equipment Co.,Ltd.

Focusing on the field of temperature calibration experimental equipment production

DY-CW Non-contact Infrared Thermometer

DY-CW Non-contact Infrared Thermometer

◇ Product Introduction ◇ Product Features◇ Technical Indicator

[Technical indicators]

DY-CW non-contact infrared thermometer/non-contact body temperature tester using Switzerland imported sensor, high accuracy, good stability, small size, can realize bracket installation and hanging installation for non-contact temperature measurement.

It mainly realizes the remote non-contact measurement and the fast measurement of ten times a second, which can greatly improve the test efficiency, avoid the contact between the staff and the tested staff, reduce the risk of contact, and alleviate the resistance of the tested staff.

Compound measurement accuracy 0.1 seconds ±0.3℃

Collection and refresh cycle: 0.1 second

Infrared lens Angle: 3°

Ideal measuring distance :(0.2~0.4) m

Ambient temperature accuracy: ±0.5℃

Alarm temperature: The screen can be set

Alarm mode: sound and light alarm and color indication of human icon on screen

Display parameters: 4 "IPS capacitive touch color display

Operating voltage: 5V

Operating current: average 250mA

Dimensions: length * width * height: 120*180*46mm

Weight: 0. kg

DY-CW Non-contact Infrared Thermometer

[Product Introduction]

[power]

1, on the power use

The device is equipped with a 2-meter USB interface power supply cable, which can use the USB interface of the computer, the charging bank and the charging head of common devices such as mobile phones to power the device.

The average working current of the device is 250mA, and most USB interface devices can meet the power supply requirements.

If the common 10000mAh charger is used to power the device, the theoretical working time can reach 40 hours.

When the power is switched on, the equipment starts to work automatically.

2, the main interface operation instructions

DY-CW Non-contact Infrared Thermometer

Ambient temperature: the current ambient temperature value, real-time update;

Number of people counted: since the boot to the current detected number of people counted, shutdown data is not saved;

Number of alarms: the number of alarms detected from startup to the current number, shutdown data is not saved;

Measurement mode switch: it is used to switch the object mode and the human body mode. The object mode is the original temperature of the object, which is used for equipment verification and calibration and object temperature measurement.

Mannequin includes a modified formula for the body's surface temperature and the actual temperature, which is closer to the actual body temperature.

The measurement mode switch will automatically record the last value, saved after shutdown;

Setting interface skip: click skip to the setting interface;

Personnel status indicator: the personnel status is judged by the target temperature. When no one enters, it is gray; when someone enters and the temperature is normal, it is green; when someone enters and exceeds the alarm value, it is red.

Personnel stay for a long time will not repeat the count;

Target temperature value: display the current target value according to the measurement mode. When it is routinely used for human body temperature test, it is enough to maintain the human body mode by measuring the body with the mode;

3. Set the interface

DY-CW Non-contact Infrared Thermometer

[Installation and fixation]

1. Install the bottom bracket

As shown in the functional schematic diagram in Figure 4, the device has 1/4 inch screw holes at the bottom, which can be directly connected with the liftable camera bracket, mobile phone landing bracket, etc., and with the universal adjusting head, height and Angle adjustment can be realized.

2, back suspension installation

There are two sets of hanging holes on the back of the equipment.

Horizontal distance is 96mm, direct is 8mm.

Two expansion nails with large heads of no more than 8mm in diameter can be driven into the wall and then hung on the wall.

DY-CW Non-contact Infrared Thermometer

DY-CW Non-contact Infrared Thermometer

  • Online message

  • Your name
    You must fill in your title
  • TEL
    Must fill in mobile phone number
  • Email
    Required
  • Company
    Optional
  • Whatsapp/Skype
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what do you want to consult?
  • Verification code: Please fill in the calculation result.
DY-CW Non-contact Infrared Thermometer 2020-12-7 This article was read 1359 Times
Previous:DY-HT3F-D Split portable high temperature short cavity blackbody furnaceNext:DY-HT3F-D Split portable high temperature short cavity blackbody furnace

Technical

Contact us

Taian Demei Electromechanical Equipment Co.,LTD.

Address:Building A8,No.98, South Nianhua Street,Shengzhuang Town,Taishan District,Tai'an City,Shandong Province,China

Tel: +86-538-6518288

Contact: Fred Xu   Email: fred@dmthermo.com

Mobile/Wechat/Whatsapp: +86 15966019173



Taian Demei Electromechanical Equipment Co.,LTD.             Lu ICP No. 14019246-4             Publicity

桐庐县| 瓦房店市| 海安县| 花垣县| 梓潼县| 积石山| 寿阳县| 南昌县| 琼海市| 大丰市| 临海市| 田阳县| 遂溪县| 文山县| 邢台县| 苏州市| 庆城县| 会宁县| 即墨市| 镇沅| 邯郸市| 来安县| 南雄市| 库伦旗| 定结县| 乳山市| 波密县| 闽清县| 宁河县| 临颍县| 阿坝县| 沾化县| 濉溪县| 定州市| 承德市| 天台县| 胶州市| 三门峡市| 伊宁市| 潜江市| 老河口市|